Page 1 - User Manual

Mastering Analog to Digital and Digital to Analog Converter User Manual Lynx Studio Technology, Inc. www.lynxstudio.c

Page 2 - Table of Contents

Page 8 2.2 Multi-Key Commands In addition to the standard front panel controls detailed in 2.1, the Aurora has been programmed so that extended fun

Page 3 - 1 Introduction

Page 9 2.3 Back Panel Connections The Aurora has been designed for maximum flexibility to integrate smoothly into today’s studio environment. Follo

Page 4 - Aurora 8 8 -channels

Page 10 2) WORD CLOCK IN and WORD CLOCK OUT BNC connectors. WORD CLOCK IN Allows Aurora to synchronize to an external clock source. With a valid cl

Page 5 - 1.7 Operation Requirements

Page 11 2.4 Cable Connections Compatible cables for the Aurora analog and digital I/O ports are available directly through Lynx. The 25-pin D-Sub

Page 6

Page 12 2.6 Clock Settings and Connections In any system with more than one digital device, there can be only one master clock providing synchroniza

Page 7 - FRONT PANEL

Page 13 2.6.2 Aurora as Clock Slave The Aurora can synchronize to sample clock from a variety of external sources. In order to establish the Aurora

Page 8 - PEAK METERS

Page 14 2.6.3 SynchroLock The Aurora incorporates SynchroLock clock synchronization technology to provide extreme tolerance to noisy external AES/EB

Page 9 - TRIM/AES MODE

Page 15 3 Common Studio Setups The Aurora has been designed to operate effectively in a variety of audio production contexts. The purpose of this

Page 10 - Dual Wire Select Mode

Page 16 3.1.1 Clock settings To use the Aurora as the clock master, select “INT” as the SYNC SOURCE from the Aurora front panel. Also, select the

Page 11 - BACK PANEL

Page 17 3.2 Aurora 16 in computer recording system with AES16/AES16e This configuration facilitates 16 channels of Analog input and output to a comp

Page 12 - 2! AC POWER INLET

User Manual Table of Contents 1 Introduction ...

Page 13 - 2.4 Cable Connections

Page 18 3.2.1 Clock settings Clock settings should be established from the Lynx Mixer and the Aurora front panel. The Aurora should be SYNC SOURC

Page 14

Page 19 3.3 Aurora 8 in Computer System with LynxTWO/L22 This configuration augments the on-board connections of a LynxTWO or L22 card with 8-channe

Page 15

Page 20 3.3.1 Clock settings Since the Aurora will be the master clock, the SYNC SOURCE should be set to “INT”. The LynxTWO/ L22 should have the

Page 16

Page 21 3.4 Standalone Format Converter In addition to AD and DA conversion, the Aurora is well suited to function as a digital format converter or

Page 17 - 3 Common Studio Setups

Page 22 4 Front Panel Key Combinations Aurora functionality can be altered via its front panel with key combinations or by depressing certain

Page 18

Page 23 5 Troubleshooting Unit will not turn on: Check the following: • Is the AC Power Cord securely connected to the AC port on the Aurora, and

Page 19

Page 24 SynchroLock LED does not illuminate: This indicates that the SynchroLock clocking system cannot lock to the selected clock source. Check the

Page 20

Page 25 6 EMC Certifications 6.1 FCC DECLARATION OF CONFORMITY TRADE NAME: A/D and D/A Converter MODEL NUMBER: Aurora 8, Aurora 16 COMPLIANCE TE

Page 21

Page 26 6.3 CE SAFETY DECLARATION OF CONFORMITY MANUFACTURERS NAME: Lynx Studio Technology, Inc. MANUFACTURER ADDRESS: 190 McCormick Avenue Cost

Page 22

Page 27 7 Support We are devoted to making your experience with the Aurora trouble-free and productive. If the troubleshooting and operational se

Page 23

Page 1 1 Introduction Thank you for choosing the Lynx Aurora 8™ / Aurora 16™ mastering AD/DA converter. The Aurora has been designed to provide y

Page 24 - Button Action Result

Page 28 8 Warranty Information One year Free Labor / One year Parts Exchange This product must be returned to the factory for repair. Who Is Cov

Page 26

Aurora User Manual, Revised November 17, 2014. Copyright © 2013, Lynx Studio Technology, Inc.

Page 27 - 6 EMC Certifications

Page 2 audio interface, from an installed and operational LT-USB or LT-TB card, or with a connected and operational MIDI Interface. 1.2 Features ¾

Page 28 - Page 26

Page 3 1.4 In the Box The following items are included in your Aurora carton: ¾ Aurora Rack-Mount Converter ¾ AC Power Cord ¾ Aurora QuickStart

Page 29 - 7 Support

Page 4 The Aurora’s analog I/O can be used with balanced or unbalanced line level devices operating at a nominal trim level of +4dBu or –10dBV (switc

Page 30 - 8 Warranty Information

Page 5 2 Operational Overview 2.1 Front Panel Controls and Indicators The Aurora allows extensive parameter selection and configuration from conv

Page 31

Page 6 No LED SynchroLock is disabled by remote control or the source is outside of SynchroLock range and the Aurora has reverted back to the wide-r

Page 32

Page 7 inputs and outputs and the TRIM/AES MODE button still displays and controls the TRIM value. However, if the unit is in “DUAL WIRE SELECT” Mode