Mastering Analog to Digital and Digital to Analog Converter User Manual Lynx Studio Technology, Inc. www.lynxstudio.c
Page 8 2.2 Multi-Key Commands In addition to the standard front panel controls detailed in 2.1, the Aurora has been programmed so that extended fun
Page 9 2.3 Back Panel Connections The Aurora has been designed for maximum flexibility to integrate smoothly into today’s studio environment. Follo
Page 10 2) WORD CLOCK IN and WORD CLOCK OUT BNC connectors. WORD CLOCK IN Allows Aurora to synchronize to an external clock source. With a valid cl
Page 11 2.4 Cable Connections Compatible cables for the Aurora analog and digital I/O ports are available directly through Lynx. The 25-pin D-Sub
Page 12 2.6 Clock Settings and Connections In any system with more than one digital device, there can be only one master clock providing synchroniza
Page 13 2.6.2 Aurora as Clock Slave The Aurora can synchronize to sample clock from a variety of external sources. In order to establish the Aurora
Page 14 2.6.3 SynchroLock The Aurora incorporates SynchroLock clock synchronization technology to provide extreme tolerance to noisy external AES/EB
Page 15 3 Common Studio Setups The Aurora has been designed to operate effectively in a variety of audio production contexts. The purpose of this
Page 16 3.1.1 Clock settings To use the Aurora as the clock master, select “INT” as the SYNC SOURCE from the Aurora front panel. Also, select the
Page 17 3.2 Aurora 16 in computer recording system with AES16/AES16e This configuration facilitates 16 channels of Analog input and output to a comp
User Manual Table of Contents 1 Introduction ...
Page 18 3.2.1 Clock settings Clock settings should be established from the Lynx Mixer and the Aurora front panel. The Aurora should be SYNC SOURC
Page 19 3.3 Aurora 8 in Computer System with LynxTWO/L22 This configuration augments the on-board connections of a LynxTWO or L22 card with 8-channe
Page 20 3.3.1 Clock settings Since the Aurora will be the master clock, the SYNC SOURCE should be set to “INT”. The LynxTWO/ L22 should have the
Page 21 3.4 Standalone Format Converter In addition to AD and DA conversion, the Aurora is well suited to function as a digital format converter or
Page 22 4 Front Panel Key Combinations Aurora functionality can be altered via its front panel with key combinations or by depressing certain
Page 23 5 Troubleshooting Unit will not turn on: Check the following: • Is the AC Power Cord securely connected to the AC port on the Aurora, and
Page 24 SynchroLock LED does not illuminate: This indicates that the SynchroLock clocking system cannot lock to the selected clock source. Check the
Page 25 6 EMC Certifications 6.1 FCC DECLARATION OF CONFORMITY TRADE NAME: A/D and D/A Converter MODEL NUMBER: Aurora 8, Aurora 16 COMPLIANCE TE
Page 26 6.3 CE SAFETY DECLARATION OF CONFORMITY MANUFACTURERS NAME: Lynx Studio Technology, Inc. MANUFACTURER ADDRESS: 190 McCormick Avenue Cost
Page 27 7 Support We are devoted to making your experience with the Aurora trouble-free and productive. If the troubleshooting and operational se
Page 1 1 Introduction Thank you for choosing the Lynx Aurora 8™ / Aurora 16™ mastering AD/DA converter. The Aurora has been designed to provide y
Page 28 8 Warranty Information One year Free Labor / One year Parts Exchange This product must be returned to the factory for repair. Who Is Cov
Aurora User Manual, Revised November 17, 2014. Copyright © 2013, Lynx Studio Technology, Inc.
Page 2 audio interface, from an installed and operational LT-USB or LT-TB card, or with a connected and operational MIDI Interface. 1.2 Features ¾
Page 3 1.4 In the Box The following items are included in your Aurora carton: ¾ Aurora Rack-Mount Converter ¾ AC Power Cord ¾ Aurora QuickStart
Page 4 The Aurora’s analog I/O can be used with balanced or unbalanced line level devices operating at a nominal trim level of +4dBu or –10dBV (switc
Page 5 2 Operational Overview 2.1 Front Panel Controls and Indicators The Aurora allows extensive parameter selection and configuration from conv
Page 6 No LED SynchroLock is disabled by remote control or the source is outside of SynchroLock range and the Aurora has reverted back to the wide-r
Page 7 inputs and outputs and the TRIM/AES MODE button still displays and controls the TRIM value. However, if the unit is in “DUAL WIRE SELECT” Mode